日韩一区和二区,久久免费av电影,国语对白做受xxxxx在,女人高潮91喷水女王偷拍,亚洲精品国产综合99久久夜夜嗨 http://www.whjsdny.com Fri, 02 Feb 2024 02:52:20 +0000 en hourly 1 http://wordpress.org/?v=3.1 3 dB原則(法則) – DTX-1800/DSX2-8000 CableAnalyzer http://www.whjsdny.com/archives/3db-rule.html http://www.whjsdny.com/archives/3db-rule.html#comments Thu, 05 Jul 2018 08:12:39 +0000 深圳連訊 http://www.whjsdny.com/?p=10078 A YouTube video explaining how this this works is also?available from here.

This is applicable to ALL test limits in the DTX CableAnalyzer where a Return Loss measurement is made.

When?the Insertion Loss is less than 3.0 dB at the frequency point where the measurement is made, then the Return Loss measurement is ignored and not evaluated against the selected Test Limit/Cabling Standard in the DTX CableAnalyzer.This is often referred to as the?3 dB rule.It applies to ALL cabling standards/test limits in the DTX CableAnalyzer.

On a short?link,
the Insertion Loss may never reach 3.0 dB.If that were to happen, then the entire measurement would be?ignored, or as the cabling standards phrase it; “recorded for information only”.If this were to happen with your DTX CableAnalyzer, you would see an “i” appear next to the summary result for that test parameter.In LinkWare software, the result would be recorded with “N/A’.An example is shown below:

Concern is normally caused when the result has a negative margin.In this example we see the Return Loss margin was -2.2. A?negative margin is normally associated with a FAIL, but because the entire link never exceeded 3.0 dB Insertion Loss, it is not a FAIL.

Let’s review in detail how this works by looking at another example test result.

A TIA Cat 5e Perm.Link AUTOTEST was run on a 29.0 m installed link, giving the following result:

Looks normal – very nice margins.Let’s take a look at the Return Loss result in a little more detail:

You will observe that?the limit line has two colors, black and red.The cabling standards do not require the cable tester manufacturer to display where the?3 dB rule is implemented to the user, only that it is implemented.However, the DTX CableAnalyzer will indicate where the 3 dB rule has been implemented by changing the color of the limit line.If the?limit line is black, it?indicates that the Insertion Loss was less than 3.0 dB.If the?limit line is red, the Insertion Loss was 3.0 dB or greater.So for this Pair 3,6 the Return Loss?is not evaluated below 29.3 MHz. Let’s take a quick look at the Insertion Loss for Pair 3,6:

As you can see, the Insertion Loss reached 3.0 dB at 29.3 MHz, as previously indicated in the Return Loss Pair 3,6 graph above.

It’s an interesting rule, because if it were not in place, our margin for the above result would reduce from 10.2 dB to 9.0 dB:

As previously mentioned, if the link is particularly short, then the Insertion Loss may never reach 3.0 dB and the entire Return Loss?result is “ignored”.Let’s take a closer look at the first example where the test result was:

Looking at the worst case Return Loss result, we see the entire limit line is black, suggesting that the Insertion Loss for Pair?3,6 never reached 3.0 dB:

Looking at the Insertion Loss for Pair 3,6:

We see that the Insertion did indeed never reach 3.0 dB, so the entire measurement is not evaluated against the limit line (ignored) and recorded as “i” Information Only.If this result was downloaded to LinkWare Software, the report would show N/A against this measurement:

No further action is required by the installer.This is a valid standards compliant result.

 

]]>
http://www.whjsdny.com/archives/3db-rule.html/feed 0
主站蜘蛛池模板: 西宁市| 东莞市| 曲松县| 五家渠市| 手机| 广丰县| 洛隆县| 赤城县| 枣强县| 扬州市| 横峰县| 通河县| 舞钢市| 刚察县| 阿拉善右旗| 沂源县| 竹北市| 苏尼特右旗| 始兴县| 凌海市| 江门市| 应城市| 甘谷县| 永寿县| 高台县| 兴海县| 江达县| 新泰市| 苏尼特右旗| 乌拉特前旗| 广丰县| 吉林市| 磐安县| 塔城市| 邵阳县| 滨州市| 临城县| 吉安市| 池州市| 台南市| 呼图壁县| 侯马市| 黔东| 白水县| 灌阳县| 淮安市| 永安市| 龙江县| 曲水县| 怀柔区| 北海市| 韶山市| 中超| 玛曲县| 保山市| 明水县| 扎兰屯市| 桐乡市| 抚宁县| 怀来县| 仲巴县| 鄂托克旗| 叙永县| 泰和县| 汝城县| 彭水| 宣汉县| 曲靖市| 中西区| 岳普湖县| 商水县| 大邑县| 阜新市| 巴马| 漳浦县| 吉安县| 自贡市| 宁海县| 肥东县| 中西区| 石首市| 静海县|